Other Publications

Other Publications or Media Coverage in the last five years.  Due to the multi-author publications in subatomic physics, only the lead author is indicated on publications with more than 10 authors.  The numbering corresponds to my Curriculum Vitae.

Media Appearances: TV (9), Radio (6), Newspaper (10), Press Releases (10).

Other Publications

73) E. Smith, M. Dugger, Z. Papandreou, Report to the physics working group on the pi0/eta asymmetry paper,   GlueX-doc-3174, October 28, 2016. 

72) A. Foda,  Z. Papandreou, E. Smith, BCAL LED, GlueX-doc-3191, November 20, 2016.

71) A.Yu. Semenov, Z. Papandreou, I. Semenova, Timing Calibration of the BCAL using F1TDCs,   GlueX-doc-3165, October 20, 2016. 

70) Z. Papandreou, Construction of the GlueX Barrel Calorimeter, GlueX Technical Report,  GlueX-doc-3164, October 16, 2016.

69) Z. Papandreou and R.T. Jones, GlueX Diamond Scan - II, Canadian Light Source Proposal 24-8235, Approved, September 2016.

68) C. Henschel, T. Beattie and  Z. Papandreou, Feasibility of Michel Electron Calibration for the Barrel Calorimeter in the GlueX Experiment,  GlueX-doc-3097, August 16, 2016.

67) Z. Papandreou and R.T. Jones, GlueX Diamond Scan - I, Canadian Light Source Proposal 24-8117, Approved, August 2016.

66) N. Ochoa,  Z. Papandreou and A. Semenov, Optimization of the Time-walk correction procedure for the GlueX Barrel Calorimeter, GlueX Technical Report,  GlueX-doc-2898, December 29, 2015.

65) T. Beattie,  Z. Papandreou and A. Semenov, GlueX Simulation and Reconstruction Development, GlueX Technical Report, GlueX-doc-2821, October 6, 2015.

64) A. Foda, Z. Papandreou and E. Smith, Efficiency in BCAL Mods 7/8, GlueX Technical Report, GlueX-doc-2817, October 1, 2015.

63) Z. Papandreou, Barrel Calorimeter Simulation Summary, GlueX Technical Report, GlueX-doc-2694, May 13, 2015.

62) T. Beattie, M. La Posta, Z. Papandreou, J. Sanchez-Fortun Stoke1, A. Yu. Semenov, M. Singh, Prototype of a Personal Radiation Detector: A Report on the 2013-2014 Collaboration Between EIC and SPARRO, Technical Report, September 10, 2014.

61) T. Beattie, Z. Papandreou, J. Sanchez-Fortun Stoker, A. Semenov. Personal Radiation Detector Report, Technical Report, July 20, 2014.

60) T. Beattie, Z. Horvath, Z. Papandreou, J. Sanchez-Fortun Stoker, A. Yu. Semenov, L. Teigrob, Methods in Measuring the Relationship Between SiPM Breakdown Voltage and Temperature, Technical Report, January 21, 2014.

59) Z. Papandreou, BCAL Calibration and Conditions Parameters, GlueX Technical Report, GlueX-doc-2379, December 17, 2013.

58) P. Babyn et al., The Saskatchewan Program for Nuclear Imaging, Letter of Intent to the Sylvia Fedoruk Canadian Centre for Nuclear Innovation for $5 million to fund faculty positions at UofS and UofR, December 15, 2013.

57) Z. Papandreou, The Barrel Calorimeter, Chapter of the GlueX Technical Design Report, 40 pages, August 2013.

56) Z. Papandreou, History and Results of the Barrel Calorimeter Development, GlueX Technical Report, GlueX-doc-2245, June 14, 2013.

55) L.A. Teigrob and Z. Papandreou, BCAL Dimensions and Weights - Updated, GlueX-doc-664-v4, May 2, 2013.

54) D. Kolybaba et al., Beam Test of the Mini BCAL SiPM Array Readout, GlueX Technical Report, GlueX-doc-2121, December 2012.

53) Y. Cao et al., Performance of Kuraray SCSF-78MJ scintillating fibres for the GlueX Barrel Calorimeter, GlueX Technical Report, GlueX-doc-1956, April 2012.

52) G.J. Lolos et al., Proposal for Beam Test of a GlueX Barrel Calorimeter Prototype in Hall B, GlueX Proposal to the 12~GeV Project, GlueX-doc-1900, March 2012.

51) S. Katsaganis and Z. Papandreou, BCAL Beam Test Analysis 2011: Forward Angles, GlueX Technical Report, GlueX-doc-1889, January 2012.